OXYGEN ANALYZERS Model 100P and Model 100F

DESCRIPTION
EAS offers two oxygen analyzer options:
A. Low cost, reliable galvanic fuel cell (Model 100F)
B. High performance compact paramagnetic sensor (Model 100P). Both read directly in percent oxygen. Both have multiple ranges and multiple linear outputs. They may be configured as stand-alone analyzers or teamed with our NDIR Series 200 or 300 to deliver a multicomponent solution to your gas analysis requirements.

FEATURES Model 100P (Paramagnetic)

  • Multiple ranges
  • Remote range change
  • Temperature controlled
  • Resolution of 10 ppm
  • High stability
  • Low interference to other gases
  • Fast response
  • Linear output
  • Digital concentration display
  • No routine cell maintenance
  • Internal pump option

FEATURES Model 100F (Galvanic Fuel Cell)

  • Low cost· Multiple ranges
  • Reliable· Remote range change
  • Linear output· Rapid response
  • Digital concentration display
  • Internal pump option

 

Model O2Oxygen Analyzer
The Model O2 is a versatile, research grade oxygen analyzer measuring 5 to 100% oxygen. The unit includes gas sampling pump, flow controller, LED display, touch panel controls for alarm, flow, and calibration functions, analog and digital RS 232 outputs, and 95 to 250 VAC input at half the cost of competitive units. The Model O2 has US FDA and CE MDD clearances to market in human medical use applications in addition to industrial and other research uses. Software included writes data to Excel graphs. For portable operation, a battery and carrying case accessory is offered.
Model O2T Transfill Oxygen Analyzer
The Model O2T oxygen monitor is designed for transfillers to verify the strength and identity of medical grade USP oxygen. This unit meets the FDA requirements under 21CFR211 for this application. The analyzer measures oxygen/nitrogen mixtures near 100% with an accuracy of 0.1% and features an electronic flow meter and touch panel controls for calibration. A calibration kit accessory is available comprising certified cal gases, regulators, and flow control accessories.
Model O2LHigh Resolution Oxygen Analyzer

The Model O2L measures oxygen in air mixtures for industrial applications with a resolution of 100 ppm from 0 to 10% or with a resolution of 0.1% from 0 to 100%. In addition to the features of the Model O2, the O2L offers a 4-20 mA analog output and four front-panel-programmable alarm contacts. This unit is used, for example, in fuel mixture and combustion emissions analysis.
Models X1003/X1004/X1007 Oxygen Sensors

These modules are designed for incorporation in OEM instrument applications. An RS-232 interface and software interface guide is provided. An analog output may also be used with a buffer amplifier. Input power is +5, +/- 15 V.

The X1003 is designed for anesthesia gas monitors. It is accurate in any mixture of anesthetic gases and independent ambient temperature changes and flow system induced pressure changes. The 10 to 90% response time is 130 ms at a flow of 200 ml/min.

The X1004 is designed for metabolic gas exchange measurements. It has a resolution of 0.02% oxygen and accuracy of +- 0.2% in air mixtures with a response time of 100 ms at 200 ml/min.

The X1007 is designed for aircraft applications and can measure oxygen concentrations at sample and/or ambient pressures of 20 to 115 kPa.

back to top

back to oxygen analyzers

 

 

 