| EAS is proud to welcome |
 |
 |
SV 4B
- 2 alarm thresholds
- Fault alarm
- Built in relays
- AC/DC power supply
- Low cost
- Mounting DIN rail
- 1 fault alarm
|
 |
MX 32
- 2 independent gas alarm thresholds
per channel
- Fault alarm
- LCD display unit
- Built in relay
- AC/DC power supply
- Wall mounted enclosure
- IP 66
- 1 fault alarm per channel
|
 |
Wingas
- With or without display unit
- 2 independent gas alarm thresholds
per channel
- Fault alarm
- Integrated relays
- Remote relay box (display unit version)
- Networking: up to 32 appliances
- Wall mounted enclosure
- 1 fault alarm common to the 4 channels
|
 |
MX 42A
- Fixed or scrolling display
- 3 gas alarm thresholds
- 1 fault alarm
- Built in relays
- AC/DC power supply
- Wall mounted enclosure
|
 |
MX 48
- Fixed or scrolling display
- 3 programmable alarm thresholds per
channel
- Fault alarm
- 4-20 mA output per channel
- RS 232 and RS 485 output
- 1 fault alarm per channel
|
 |
MX 52
- Fixed or scrolling display of measurements
- 3 programmable alarm thresholds per
channel
- 4-20mA output per channel
- RS 232 and RS 485 outputs
- Rack 3U, 19"
- 1 fault alarm per channel
|
 |
Vigipark
dedicated to carpark
- 10 sequential sampling channels
- Up to 4 continuous channels
- 4 instantaneous gas alarm thresholds
- 2 averaged gas alarm thresholds (1
for STEL, 1 for TWA)
- 4 instantaneous or averaged alarm thresholds
- 1 fault alarm per channel
- Rack 3U, 19"
|
 |
MX 62
- Modular, flexible
- Enhanced safety: dual micro-processor
(SIL3 of EN 954-1)
- Standard or loop wiring
- Autocontrol
- Alphanumeric LCD screen
- Data logging and serial output
- Wall mounted or free standing enclosure
- Data and alarms supervision
|
 |
DGM9
- Continuous gas: CH4,
CO2, O2, H2S (on request)
- Reliable and accurate measurement
- Long life span
|
| Detectors-Transmitters for flammable/toxic gases and
oxygen |
 |
CTX 300
- Robust enclosure
- Pre calibrated interchangeable sensor
block
- Backlit LCD display optional
- 2 or 3 wires
- IP 66
|
 |
OLCT 20(FLP) & 20D (IS)
- 2 wires for Ox/toxic gases/3 wires
for flammable gases
- Pre calibrated interchangeable sensor
block
- Output 4-20mA, 24 VDC
- Approval d or i
- Fixation on housing
- IP 66
- Remote version: 15 m. cable (OLCT 20D)
|
 |
OLCT 40
- Robust enclosure
- Pre calibrated interchangeable sensor
block
- 2 or 3 wires (2 for OX/toxic gases/3
for LEL)
- IP 66
- Output 4-20mA
- Remote version: 15 m. cable (OLCT 40D)
|
 |
OLCT 50
- Flameproof housing
- Pre calibrated interchangeable sensor
block
- 2 or 3 wires (2 for OX/toxicgases/3
for LEL)
- IP 66
- Output 4-20mA, 24 VDC
- Approval d or i
- Remote version: 15 m. cable (OLCT 50D)
|
 |
OLCT 60A
- 3 wires with local display
- Maintenance by magnetic switch
- Flameproof housing
- Pre calibrated interchangeable sensor
block
- Output 4-20 mA
- IP 66
- Remote version: 15 m. cable (OLCT 60AD)
|
Infrared Transmitter for CO2/Flame Detector/Infrared
Flammable Gas Detector/Transmitter |
 |
TCOD IR Infrared Transmitter
for CO2
- Gas detected: CO2
- Selective absorption IR sensor block
- Long life span
- Robust
- Quick response time
|
 |
SHARPEYE Flame Detector
- Approved for classified areas
- UV-UV/IR-IR3 technology
- False alarm protected
- 90° cone of vision
- Flameproof type "d"
|
 |
GD 10 Infrared flammable
gas detector/transmitter
- Designed for harsh environments
- Infrared technology
- CENELEC approval
|

| Ultrasonic Gas Leak Detectors |
INNOVA
GasSonic manufactures ultrasonic gas leak detection systems for fixed installation
in the on-/offshore industry and other hazardous plant installations.
All traditional fixed gas detection systems has one major weakness:
Potentially explosive gas leaks are only detected if the escaping gas is actually
reaching the traditional gas detectors. In the meantime this can be very unlikely
in outdoor locations such as off-shore installations.
In
outdoor installations the escaping gas is often very quickly diluted or drifted
away by the wind, therefore a potential leak can last for a very long time before
it is detected.
A recognized alternative or supplement to existing gas detection technologies
(Infrared Point, Infrared Open-path or Catalytic Point sensors) is the ultrasonic
Gas Leak Detector MM0100 that offers an airborne acoustic detection of gas leaks.
Only ultrasonic gas leak detection offers gas leak detection coverage in 5
10 metres diameter around the detector WITHOUT being affected by changing weather
conditions.
back to top
home
sitemap
EAS service
links
testimonials
contact us 
Environmental
Analytical Systems
286 Mask Island Drive
Barry's Bay, Ontario, Canada K0J 1B0
Phone:
613 756 0101
Toll Free (Canada only):
1 800 427 8591
Fax: 613 756 0909
email: info@enviro-analytical.com
©Environmental
Analytical Systems 2003